1.
Ann Card Anaesth ; 27(1): 51-52, 2024 Jan 01.
Article En | MEDLINE | ID: mdl-38722121

ABSTRACT: The quadricuspid aortic valve is a rare congenital anomaly, usually associated with aortic regurgitation requiring surgical intervention. It may be associated with other congenital anomalies such as coronary anomalies, patent ductus arteriosus, ventricular septal defect, pulmonary stenosis, and subaortic stenosis. The diagnosis is generally established by either transthoracic or transesophageal echocardiography. Herein, we report a case of a 52-year-old woman who was diagnosed to have quadricuspid aortic valve by intraoperative transesophageal echocardiography.


Aortic Valve , Echocardiography, Transesophageal , Humans , Female , Aortic Valve/abnormalities , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Middle Aged , Echocardiography, Transesophageal/methods , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/diagnostic imaging , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/surgery
2.
Ann Card Anaesth ; 27(1): 53-57, 2024 Jan 01.
Article En | MEDLINE | ID: mdl-38722122

ABSTRACT: Aortic valve (AV) repair is the desired surgical treatment option for young patients with aortic regurgitation (AR). It is considered as a class I indication for the surgical treatment of severeAR. The success of an AV repair depends on the detailed intraoperative transesophageal echocardiographic (TEE) examination which should fulfil the information required by the surgeon. The objective of this echo round is to describe the role of intraoperative TEE in systematic evaluation of the AV, before and after repair.


Aortic Valve Insufficiency , Aortic Valve , Echocardiography, Transesophageal , Monitoring, Intraoperative , Humans , Echocardiography, Transesophageal/methods , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Child , Monitoring, Intraoperative/methods
3.
EuroIntervention ; 20(9): 579-590, 2024 May 10.
Article En | MEDLINE | ID: mdl-38726714

BACKGROUND: Data on the performance of the latest-generation SAPIEN 3 Ultra RESILIA (S3UR) valve in patients who undergo transcatheter aortic valve replacement (TAVR) are scarce. AIMS: We aimed to assess the clinical outcomes, including valve performance, of the S3UR. METHODS: Registry data of 618 consecutive patients with S3UR and of a historical pooled cohort of 8,750 patients who had a SAPIEN 3 (S3) valve and underwent TAVR were collected. The clinical outcomes and haemodynamics, including patient-prosthesis mismatch (PPM), were compared between the 2 groups and in a propensity-matched cohort. RESULTS: The incidence of in-hospital death, vascular complications, and new pacemaker implantation was similar between the S3UR and the S3 groups (allp>0.05). However, both groups showed significant differences in the degrees of paravalvular leakage (PVL) (none-trivial: 87.0% vs 78.5%, mild: 12.5% vs 20.5%, ≥moderate: 0.5% vs 1.1%; p<0.001) and the incidence of PPM (none: 94.3% vs 85.1%, moderate: 5.2% vs 12.8%, severe: 0.5% vs 2.0%; p<0.001). The prevalence of a mean pressure gradient ≥20 mmHg was significantly lower in the S3UR group (1.6% vs 6.2%; p<0.001). Better haemodynamics were observed with the smaller 20 mm and 23 mm S3UR valves. The results were consistent in a matched cohort of patients with S3UR and with S3 (n=618 patients/group). CONCLUSIONS: The S3UR has equivalent procedural complications to the S3 but with lower rates of PVL and significantly better valve performance. The better valve performance of the S3UR, particularly in smaller valve sizes, overcomes the remaining issue of balloon-expandable valves after TAVR.


Aortic Valve Stenosis , Aortic Valve , Heart Valve Prosthesis , Registries , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/methods , Female , Male , Aged, 80 and over , Aged , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Treatment Outcome , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Prosthesis Design , Hemodynamics , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Hospital Mortality
4.
EuroIntervention ; 20(9): 536-550, 2024 May 10.
Article En | MEDLINE | ID: mdl-38726720

The identification and management of patients at high bleeding risk (HBR) undergoing transcatheter aortic valve implantation (TAVI) are of major importance, but the lack of standardised definitions is challenging for trial design, data interpretation, and clinical decision-making. The Valve Academic Research Consortium for High Bleeding Risk (VARC-HBR) is a collaboration among leading research organisations, regulatory authorities, and physician-scientists from Europe, the USA, and Asia, with a major focus on TAVI-related bleeding. VARC-HBR is an initiative of the CERC (Cardiovascular European Research Center), aiming to develop a consensus definition of TAVI patients at HBR, based on a systematic review of the available evidence, to provide consistency for future clinical trials, clinical decision-making, and regulatory review. This document represents the first pragmatic approach to a consistent definition of HBR evaluating the safety and effectiveness of procedures, devices and drug regimens for patients undergoing TAVI..


Consensus , Hemorrhage , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Risk Factors , Hemorrhage/etiology , Risk Assessment , Aortic Valve Stenosis/surgery , Aortic Valve/surgery
5.
Laeknabladid ; 110(5): 247-253, 2024 May.
Article Is | MEDLINE | ID: mdl-38713559

INTRODUCTION: One of the most serious complications of surgical aortic valve replacement (SAVR) is stroke that can result in increased rates of complications, morbidity and mortality postoperatively. The aim of this study was to investigate incidence, risk factors and short-term outcome in a well defined cohort of SAVR-patients. MATERIALS AND METHOD: A retrospective study on 740 consecutive aortic stenosis patients who underwent SAVR in Iceland 2002-2019. Patients with stroke were compared with non-stroke patients; including preoperative risk factors of cardiovascular disease, echocardiogram-results, rate of early postoperative complications other than stroke and 30 day mortality. RESULTS: Mean age was 71 yrs (34% females) with 57% of the patients receiving stented bioprosthesis, 31% a stentless Freestyle®-valve and 12% a mechanical valve. Mean EuroSCORE-II was 3.6, with a maximum preop-gradient of 70 mmHg and an estimated valvular area of 0.73 cm2. Thirteen (1.8%) patients were diagnosed with stroke where hemiplegia (n=9), loss of consciousness (n=3) and/or aphasia (n=4) were the most common presenting symptoms. In 70% of cases the neurological symptoms resolved or disappeared in the first weeks and months after surgery. Only one patient out of 13 died within 30-days (7.7%). Stroke-patients had significantly lower BMI than non-stroke patients, but other risk factors of cardiovascular diseases, intraoperative factors or the rate of other severe postoperative complications than stroke were similar between groups. Total length of stay was 14 days vs. 10 days median, including 2 vs. 1 days in the ICU, in the stroke and non-stroke-groups, respectively. CONCLUSIONS: The rate of stroke after SAVR was low (1.8%) and in line with other similar studies. Although a severe complication, most patients with perioperative stroke survived 30 days postoperatively and in majority of cases neurological symptoms recovered.


Aortic Valve Stenosis , Aortic Valve , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Stroke , Humans , Female , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/diagnostic imaging , Male , Aged , Risk Factors , Retrospective Studies , Iceland/epidemiology , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Heart Valve Prosthesis Implantation/instrumentation , Stroke/epidemiology , Stroke/mortality , Stroke/etiology , Incidence , Time Factors , Treatment Outcome , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Risk Assessment , Aged, 80 and over , Middle Aged
6.
Sci Rep ; 14(1): 10409, 2024 05 06.
Article En | MEDLINE | ID: mdl-38710782

In transcatheter aortic valve implantation (TAVI), final device position may be affected by device interaction with the whole aortic landing zone (LZ) extending to ascending aorta. We investigated the impact of aortic LZ curvature and angulation on TAVI implantation depth, comparing short-frame balloon-expanding (BE) and long-frame self-expanding (SE) devices. Patients (n = 202) treated with BE or SE devices were matched based on one-to-one propensity score. Primary endpoint was the mismatch between the intended (HPre) and the final (HPost) implantation depth. LZ curvature and angulation were calculated based on the aortic centerline trajectory available from pre-TAVI computed tomography. Total LZ curvature ( k L Z , t o t ) and LZ angulation distal to aortic annulus ( α L Z , D i s t a l ) were greater in the SE compared to the BE group (P < 0.001 for both). In the BE group, HPost was significantly higher than HPre at both cusps (P < 0.001). In the SE group, HPost was significantly deeper than HPre only at the left coronary cusp (P = 0.013). At multivariate analysis, α L Z , D i s t a l was the only independent predictor (OR = 1.11, P = 0.002) of deeper final implantation depth with a cut-off value of 17.8°. Aortic LZ curvature and angulation significantly affected final TAVI implantation depth, especially in high stent-frame SE devices reporting, upon complete release, deeper implantation depth with respect to the intended one.


Aortic Valve Stenosis , Aortic Valve , Transcatheter Aortic Valve Replacement , Transcatheter Aortic Valve Replacement/methods , Humans , Male , Female , Aged, 80 and over , Aged , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve Stenosis/surgery , Tomography, X-Ray Computed , Aorta/diagnostic imaging , Aorta/surgery , Treatment Outcome , Heart Valve Prosthesis , Retrospective Studies
7.
Port J Card Thorac Vasc Surg ; 31(1): 12-16, 2024 May 13.
Article En | MEDLINE | ID: mdl-38743522

There has been a worldwide rapid adoption of transcatheter aortic valve replacement (TAVR) as an alternative to surgical aortic valve replacement (SAVR) for patients with severe aortic stenosis. Currently, more TAVR explants with SAVRs are performed than TAVR-in TAV. TAVR explantation is a technically hazardous procedure mainly due to significant aortic neo-endothelialization which incorporates the TAVR valve. Surgical techniques for TAVR explantation are not well established and surgeon experience at present is limited. In this manuscript, we describe our technique for surgical explantation of transcatheter aortic bioprosthesis. Familiarity with the procedure and its clinical implications is essential for all cardiac surgeons.


Aortic Valve Stenosis , Bioprosthesis , Device Removal , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Aortic Valve Stenosis/surgery , Bioprosthesis/adverse effects , Device Removal/methods , Heart Valve Prosthesis/adverse effects , Aortic Valve/surgery , Aortic Valve/pathology
8.
Europace ; 26(5)2024 May 02.
Article En | MEDLINE | ID: mdl-38691562

AIMS: We examined whether thickness of the basal muscular interventricular septum (IVS), as measured by pre-procedural computed tomography (CT), could be used to identify the risk of conduction disturbances following transcatheter aortic valve replacement (TAVR). The IVS is a pivotal region of the electrical conduction system of the heart where the atrioventricular conduction axis is located. METHODS AND RESULTS: Included were 78 patients with severe aortic stenosis who underwent CT imaging prior to TAVR. The thickness of muscular IVS was measured in the coronal view, in systolic phases, at 1, 2, 5, and 10 mm below the membranous septum (MS). The primary endpoint was a composite of conduction disturbance following TAVR. Conduction disturbances occurred in 24 out of 78 patients (30.8%). Those with conduction disturbances were significantly more likely to have a thinner IVS than those without conduction disturbances at every measured IVS level (2.98 ± 0.52 mm vs. 3.38 ± 0.52 mm, 4.10 ± 1.02 mm vs. 4.65 ± 0.78 mm, 6.11 ± 1.12 mm vs. 6.88 ± 1.03 mm, and 9.72 ± 1.95 mm vs. 10.70 ± 1.55 mm for 1, 2, 5 and 10 mm below MS, respectively, P < 0.05 for all). Multivariable logistic regression analysis showed that pre-procedural IVS thickness (<4 mm at 2 mm below the MS) was a significant independent predictor of post-procedural conduction disturbance (adjOR 7.387, 95% CI: 2.003-27.244, P = 0.003). CONCLUSION: Pre-procedural CT assessment of basal IVS thickness is a novel predictive marker for the risk of conduction disturbances following TAVR. The IVS thickness potentially acts as an anatomical barrier protecting the underlying conduction system from mechanical compression during TAVR.


Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Ventricular Septum , Humans , Male , Female , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Ventricular Septum/diagnostic imaging , Aged, 80 and over , Risk Factors , Aged , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/diagnostic imaging , Heart Conduction System/physiopathology , Heart Conduction System/diagnostic imaging , Treatment Outcome , Predictive Value of Tests , Risk Assessment , Severity of Illness Index , Retrospective Studies , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Multidetector Computed Tomography , Tomography, X-Ray Computed , Action Potentials
9.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Article En | MEDLINE | ID: mdl-38710669

OBJECTIVES: The objective of this analysis was to assess the normal haemodynamic performance of contemporary surgical aortic valves at 1 year postimplant in patients undergoing surgical aortic valve replacement for significant valvular dysfunction. By pooling data from 4 multicentre studies, this study will contribute to a better understanding of the effectiveness of surgical aortic valve replacement procedures, aiding clinicians and researchers in making informed decisions regarding valve selection and patient management. METHODS: Echocardiograms were assessed by a single core laboratory. Effective orifice area, dimensionless velocity index, mean aortic gradient, peak aortic velocity and stroke volume were evaluated. RESULTS: The cohort included 2958 patients. Baseline age in the studies ranged from 70.1 ± 9.0 to 83.3 ± 6.4 years, and Society of Thoracic Surgeons risk of mortality was 1.9 ± 0.7 to 7.5 ± 3.4%. Twenty patients who had received a valve model implanted in fewer than 10 cases were excluded. Ten valve models (all tissue valves; n = 2938 patients) were analysed. At 1 year, population mean effective orifice area ranged from 1.46 ± 0.34 to 2.12 ± 0.59 cm2, and dimensionless velocity index, from 0.39 ± 0.07 to 0.56 ± 0.15. The mean gradient ranged from 8.6 ± 3.4 to 16.1 ± 6.2 mmHg with peak aortic velocity of 1.96 ± 0.39 to 2.65 ± 0.47 m/s. Stroke volume was 75.3 ± 19.6 to 89.8 ± 24.3 ml. CONCLUSIONS: This pooled cohort is the largest to date of contemporary surgical aortic valves with echocardiograms analysed by a single core lab. Overall haemodynamic performance at 1 year ranged from good to excellent. These data can serve as a benchmark for other studies and may be useful to evaluate the performance of bioprosthetic surgical valves over time. CLINICAL TRIAL REGISTRATION NUMBER: NCT02088554, NCT02701283, NCT01586910 and NCT01531374.


Aortic Valve , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Hemodynamics , Humans , Hemodynamics/physiology , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aged , Female , Male , Aged, 80 and over , Heart Valve Prosthesis Implantation/methods , Echocardiography , Middle Aged , Prosthesis Design
10.
Sci Rep ; 14(1): 10902, 2024 05 13.
Article En | MEDLINE | ID: mdl-38740898

Calcification of the aortic valve (CAVDS) is a major cause of aortic stenosis (AS) leading to loss of valve function which requires the substitution by surgical aortic valve replacement (SAVR) or transcatheter aortic valve intervention (TAVI). These procedures are associated with high post-intervention mortality, then the corresponding risk assessment is relevant from a clinical standpoint. This study compares the traditional Cox Proportional Hazard (CPH) against Machine Learning (ML) based methods, such as Deep Learning Survival (DeepSurv) and Random Survival Forest (RSF), to identify variables able to estimate the risk of death one year after the intervention, in patients undergoing either to SAVR or TAVI. We found that with all three approaches the combination of six variables, named albumin, age, BMI, glucose, hypertension, and clonal hemopoiesis of indeterminate potential (CHIP), allows for predicting mortality with a c-index of approximately 80 % . Importantly, we found that the ML models have a better prediction capability, making them as effective for statistical analysis in medicine as most state-of-the-art approaches, with the additional advantage that they may expose non-linear relationships. This study aims to improve the early identification of patients at higher risk of death, who could then benefit from a more appropriate therapeutic intervention.


Aortic Valve Stenosis , Aortic Valve , Calcinosis , Deep Learning , Humans , Aortic Valve/surgery , Aortic Valve/pathology , Calcinosis/surgery , Calcinosis/mortality , Female , Male , Aged , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Transcatheter Aortic Valve Replacement/mortality , Aged, 80 and over , Survival Analysis , Risk Factors , Proportional Hazards Models , Risk Assessment/methods , Heart Valve Prosthesis Implantation/mortality , Heart Valve Prosthesis Implantation/methods , Middle Aged
11.
Rev. esp. cardiol. (Ed. impr.) ; 77(5): 396-407, mayo 2024. tab, graf
Article Es | IBECS | ID: ibc-JHG-73

Introducción y objetivos: Existen pocos datos acerca del impacto pronóstico de una clase funcional NYHA III-IV después del implante percutáneo de válvula aórtica (TAVI). El objetivo del estudio fue determinar la incidencia, los predictores y las implicaciones pronósticas de una clase NYHA III-IV al mes del TAVI.MétodosEstudio multicéntrico que incluyó a 3.462 pacientes sometidos a TAVI que recibieron dispositivos de nueva generación. Se compararon pacientes en clase funcional NYHA I-II frente a pacientes en clase NYHA III-IV al mes de seguimiento. Los predictores de clase NYHA III-IV a un mes se identificaron mediante regresión logística multivariante. La supervivencia se evaluó con el método de Kaplan-Meier y los factores asociados a peor pronóstico se identificaron mediante la regresión de Cox.ResultadosLa edad media de la población de estudio era de 80,3±7,3 años, con el 47% de mujeres y un valor mediano en la escala de la Society of Thoracic Surgeons del 3,8% [IQR, 2,5-5,8]). Un total de 208 pacientes (6%) presentaron NYHA III-IV al mes del TAVI. Los predictores de NYHA III-IV al mes fueron: NYHA basal III-IV (OR=1,76; IC95%, 1,08-2,89; p=0,02), enfermedad pulmonar obstructiva crónica (OR=1,80; IC95%, 1,13-2,83; p=0,01) e insuficiencia mitral severa post-TAVI (OR=2,00; IC95%, 1,21-3,31; p<0,01). Los pacientes en NYHA III-IV al mes del TAVI tenían un mayor riesgo de muerte (HR=3,68; IC95%, 2,39-5,70; p<0,01) y hospitalización por insuficiencia cardiaca (HR=6,00; IC95%, 3,76-9,60; p<0,01) durante el año que siguió al TAVI. (AU)


Introduction and objectives: There are scarce data on the factors associated with impaired functional status after transcatheter aortic valve replacement (TAVR) and its clinical impact. This study aimed to determine the incidence, predictors, and prognostic implications of impaired functional class (NYHA class III-IV) following TAVR.MethodsThis multicenter study included 3462 transarterial TAVR patients receiving newer generation devices. The patients were compared according to their NYHA class at 1 month of follow-up (NYHA I-II vs NYHA III-IV). A multivariate logistic regression was performed to identify the predictors of 30-day NYHA class III-IV. Patient survival was compared with the Kaplan-Meier method and factors associated with decreased survival were identified with Cox regression analysis.ResultsThe mean age of the study population was 80.3±7.3 years, with 47% of women, and a median Society of Thoracic Surgeons score of 3.8% [IQR, 2.5-5.8]. A total of 208 patients (6%) were in NYHA class III-IV 1 month after TAVR. Predictors of 30-day NYHA class III-IV were baseline NYHA class III-IV (OR, 1.76; 95%CI, 1.08-2.89; P=.02), chronic pulmonary obstructive disease (OR, 1.80; 95%CI, 1.13-2.83; P=.01), and post-TAVR severe mitral regurgitation (OR, 2.00; 95%CI, 1.21-3.31; P<.01). Patients in NYHA class III-IV 1 month after TAVR were at higher risk of death (HR, 3.68; 95%CI, 2.39-5.70; P<.01) and heart failure-related hospitalization (HR, 6.00; 95%CI, 3.76-9.60; P<.01) at 1-year follow-up. (AU)


Humans , Aortic Valve/surgery , Postoperative Complications , Survival Rate/trends , Time Factors , Follow-Up Studies , Risk Factors
15.
J Cardiothorac Surg ; 19(1): 279, 2024 May 07.
Article En | MEDLINE | ID: mdl-38715032

OBJECTIVE: Reports on long-term outcomes of surgical aortic valve replacement (AVR) for patients aged < 60 years are scarce in Japan. Hence, we aimed to evaluate these outcomes in patients aged < 60 years. METHODS: Between March 2000 and December 2020, 1477 patients underwent aortic valve replacement. In total, 170 patients aged < 60 years who underwent aortic valve replacement were recruited. Patients aged < 18 years were excluded. Patient data collected from the operative records and follow-up assessments were reviewed. RESULTS: The mean age was 49 ± 9 years, and 64.1% of patients were male. One-hundred-and-fifty-two patients (89.4%) underwent aortic valve replacement with a mechanical valve and 18 (10.6%) with a bioprosthetic valve. The mean follow-up period was 8.1 ± 5.5 years. No operative mortality occurred, and in-hospital mortality occurred in one patient (0.6%). Ten late deaths occurred, with seven cardiac-related deaths. The overall survival rate was 95.4 ± 1.7%, 93.9 ± 2.3%, 90.6 ± 3.9%, and 73.2 ± 11.8% at 5, 10, 15, and 20 years, respectively. Freedom from major bleeding was 96.4 ± 1.6% at 5, 10, and 15 years, and 89.0 ± 7.3% at 20 years. Freedom from thromboembolic events was 98.7 ± 1.3%, 97.3 ± 1.9%, 90.5 ± 4.5%, and 79.0 ± 11.3% at 5, 10, 15, and 20 years, respectively. Freedom from valve-related reoperation was 99.4 ± 0.6% at 5 years, 97.8 ± 1.7% at 10 and 15 years, and 63.9 ± 14.5% at 20 years. CONCLUSIONS: Patients aged < 60 years undergoing aortic valve replacement with a high mechanical valve implantation rate had favorable long-term outcomes.


Aortic Valve , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Humans , Male , Middle Aged , Female , Heart Valve Prosthesis Implantation/methods , Aortic Valve/surgery , Adult , Bioprosthesis , Retrospective Studies , Postoperative Complications/epidemiology , Japan/epidemiology , Follow-Up Studies , Treatment Outcome , Survival Rate/trends , Age Factors , Time Factors , Hospital Mortality
16.
J Cardiothorac Surg ; 19(1): 281, 2024 May 07.
Article En | MEDLINE | ID: mdl-38715080

Injury to coronary arteries during mitral surgery is a rare but life-threatening procedural complication, an anomalous origin and course of the left circumflex artery (LCx) increase this risk. Recognizing the anomaly by the characteristic angiographic pattern and identifying its relationship with the surrounding anatomical structure using imaging techniques, mainly transesophageal echocardiography (TOE) or coronary computed tomography angiography (CCTA), is of crucial importance in setting up the best surgical strategy. We report a case of anomalous origin of a circumflex artery (LCx) from the proximal portion of the right coronary artery (RCA) with a pathway running retroaortically through the mitro-aortic space. An integrated diagnostic approach using a multidisciplinary team with a cardiologist and an imaging radiologist allowed us to decide the surgical strategy. We successfully performed a mitral valvular repair using a minimally invasive minithoracotomic approach and implanting a complete semirigid ring.


Aortic Valve , Coronary Vessel Anomalies , Echocardiography, Transesophageal , Mitral Valve , Humans , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/abnormalities , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/abnormalities , Coronary Vessel Anomalies/surgery , Coronary Vessel Anomalies/diagnostic imaging , Coronary Angiography , Computed Tomography Angiography , Male , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/diagnostic imaging , Female , Coronary Vessels/surgery , Coronary Vessels/diagnostic imaging
17.
Clin Interv Aging ; 19: 695-703, 2024.
Article En | MEDLINE | ID: mdl-38711477

Purpose: In mixed aortic valve disease (MAVD), the results of transcatheter aortic valve replacement (TAVR) are conflicting. There is limited data on the outcomes of TAVR in patients with bicuspid aortic valve (BAV) and MAVD. The objective of this study is to compare outcomes after TAVR in BAV patients with MAVD and predominant aortic stenosis (PAS). Patients and Methods: Patients with BAV who underwent TAVR between January 2016 and April 2023 were included. The primary outcome was device success. The secondary endpoints were periprocedural mortality and other complications as defined by the Valve Academic Research Consortium-3 (VARC-3). Propensity score matching was used to minimize potential confounding. Results: A total of 262 patients were included in this study, 83 of whom had MAVD. The median age was 72 years, and 55.7% were male. The baseline comorbidity risk files were comparable between the two groups. Patients with MAVD had more mitral regurgitation, tricuspid regurgitation and pulmonary hypertension, larger annular and left ventricular outflow tract dimensions, and more severe calcification than PAS. In the unmatched population, MAVD patients had similar device success rate (69.9% vs 79.9%, P=0.075) and 30-day mortality (3.6% vs 3.4%, P=1) compared to PAS. Propensity score matching resulted in 66 patient pairs. Device success rate were still comparable in the matched population. Other clinical outcomes, including stroke, bleeding (type 2-4), major vascular complications, acute kidney injury (stage 2-4) and permanent pacemaker implantation, were comparable between the two groups. Multivariable logistic regression analysis did not show MAVD to be an independent negative predictor of device success. At one year, survival was similar between patients with MAVD and those with PAS. Conclusion: For the bicuspid valve, patients with MAVD had a more challenging anatomy. MAVD patients associated with comparable 30-day clinical outcomes after TAVR compared to PAS patients in patients with BAV.


Aortic Valve Stenosis , Bicuspid Aortic Valve Disease , Postoperative Complications , Propensity Score , Transcatheter Aortic Valve Replacement , Humans , Male , Female , Aortic Valve Stenosis/surgery , Aged , Bicuspid Aortic Valve Disease/surgery , Aged, 80 and over , Postoperative Complications/epidemiology , Retrospective Studies , Treatment Outcome , Aortic Valve/surgery , Aortic Valve/abnormalities , Middle Aged , Risk Factors , Heart Valve Diseases/surgery
19.
Cardiovasc Toxicol ; 24(5): 499-512, 2024 May.
Article En | MEDLINE | ID: mdl-38589550

Calcific aortic valve stenosis (CAVS) is characterized by increasing inflammation and progressive calcification in the aortic valve leaflets and is a major cause of death in the aging population. This study aimed to identify the inflammatory proteins involved in CAVS and provide potential therapeutic targets. We investigated the observational and causal associations of 92 inflammatory proteins, which were measured using affinity-based proteomic assays. Firstly, the case-control cohort identified differential proteins associated with the occurrence and progression of CAVS. Subsequently, we delved into exploring the causal impacts of these associated proteins through Mendelian randomization. This involved utilizing genetic instruments derived from cis-protein quantitative loci identified in genome-wide association studies, encompassing a cohort of over 400,000 individuals. Finally, we investigated the gene transcription and protein expression levels of inflammatory proteins by single-cell and immunohistochemistry analysis. Multivariate logistic regression and spearman's correlation analysis showed that five proteins showed a significant positive correlation with disease severity. Mendelian randomization showed that elevated levels of two proteins, namely, matrix metallopeptidase-1 (MMP1) and sirtuin 2 (SIRT2), were associated with an increased risk of CAVS. Immunohistochemistry and single-cell transcriptomes showed that expression levels of MMP1 and SIRT2 at the tissue and cell levels were significantly higher in calcified valves than in non-calcified control valves. These findings indicate that MMP1 and SIRT2 are causally related to CAVS and open up the possibility for identifying novel therapeutic targets.


Aortic Valve Stenosis , Aortic Valve , Aortic Valve/pathology , Biomarkers , Calcinosis , Inflammation Mediators , Matrix Metalloproteinase 1 , Mendelian Randomization Analysis , Proteomics , Humans , Aortic Valve Stenosis/metabolism , Aortic Valve Stenosis/blood , Aortic Valve Stenosis/pathology , Aortic Valve Stenosis/genetics , Calcinosis/genetics , Calcinosis/metabolism , Calcinosis/blood , Calcinosis/pathology , Aortic Valve/metabolism , Male , Female , Aged , Case-Control Studies , Biomarkers/blood , Inflammation Mediators/metabolism , Inflammation Mediators/blood , Matrix Metalloproteinase 1/genetics , Matrix Metalloproteinase 1/metabolism , Middle Aged , Risk Factors , Severity of Illness Index , Aged, 80 and over , Genetic Predisposition to Disease , Blood Proteins/genetics , Blood Proteins/analysis , Phenotype
20.
J Am Heart Assoc ; 13(9): e033846, 2024 May 07.
Article En | MEDLINE | ID: mdl-38639328

BACKGROUND: Next-day discharge (NDD) outcomes following uncomplicated self-expanding transcatheter aortic valve replacement have not been studied. Here, we compare readmission rates and clinical outcomes in NDD versus non-NDD transcatheter aortic valve replacement with Evolut. METHODS AND RESULTS: Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry patients (n=29 597) undergoing elective transcatheter aortic valve replacement with self-expanding supra-annular valves (Evolut R, PRO, and PRO+) from July 2019 to June 2021 were stratified by postprocedure length of stay: ≤1 day (NDD) versus >1 day (non-NDD). Propensity score matching was used to compare risk adjusted 30-day readmission rates and 1-year outcomes in NDD versus non-NDD, and multivariable regression to determine predictors of NDD and readmission. Between the first and last calendar quarter, the rate of NDD increased from 45.4% to 62.1% and median length of stay decreased from 2 days to 1. Propensity score matching produced relatively well-matched NDD and non-NDD cohorts (n=10 549 each). After matching, NDD was associated with lower 30-day readmission rates (6.3% versus 8.4%; P<0.001) and 1-year adverse outcomes (death, 7.0% versus 9.3%; life threatening/major bleeding, 1.6% versus 3.4%; new permanent pacemaker implantation/implantable cardioverter-defibrillator, 3.6 versus 11.0%; [all P<0.001]). Predictors of NDD included non-Hispanic ethnicity, preexisting permanent pacemaker implantation/implantable cardioverter-defibrillator, and previous surgical aortic valve replacement. CONCLUSIONS: Most patients undergoing uncomplicated self-expanding Evolut transcatheter aortic valve replacement are discharged the next day. This study found that NDD can be predicted from baseline patient characteristics and was associated with favorable 30-day and 1-year outcomes, including low rates of permanent pacemaker implantation and readmission.


Aortic Valve Stenosis , Patient Discharge , Patient Readmission , Propensity Score , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/trends , Patient Readmission/statistics & numerical data , Patient Readmission/trends , Male , Female , Aged, 80 and over , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Aged , Patient Discharge/trends , Registries , Length of Stay/statistics & numerical data , Length of Stay/trends , Time Factors , Heart Valve Prosthesis , Postoperative Complications/epidemiology , Treatment Outcome , United States/epidemiology , Risk Factors , Aortic Valve/surgery , Retrospective Studies , Prosthesis Design , Risk Assessment
...